Water Source
Connect the color-coded “hot”
wire from the Master Valve or
Pump Start Relay to the Timer
terminal marked MASTER
(MSTR) VALVE.
Connect the common wire
from the Master Valve or Pump
Start Relay to the common wire
coming from the station valves.
This wire connects to the Timer
terminal marked COMMON.
To avoid possible pump damage,
connect a short “jumper”
wire from any unused station
terminal(s) to the nearest
terminal screw in use. For
example, if you have a
6-station timer with
only 4 stations in
use, route stations
5–6 to the nearest active
station (in this case, 4).
Simple To Set Timer New Installation Guide
What is an Automatic Sprinkler System?
1
What will you need?
2
Mounting your Timer to the wall
3
Connecting the Valve Wires: Common
5a
Connecting Rain Sensor
6
Connecting the Power Cord
4
Timer
Valve Control Wiring
Valves
Sprinkler Zone
1
2
3
4
(Number of Zones vary by Timer Model)
Supplies not included with timer
• Valve Control wire; for new systems
18 gauge color coded, multi-strand, direct-burial wire
for runs less than 800 feet; 14 gauge for runs greater
than 800 feet
• Water tight splice connectors
• Drywall anchors; optional
Tools you will need to install timer
• Phillips screwdriver
• Wire strippers
• Hammer
Locate a spot indoors for your Timer.
Locate Timer so that it is convenient to run control wires.
Locate Timer within 5 feet of an AC power outlet.
Locate Timer at least 15 feet away from major appliances
and air conditioners.
Attach connector to
24VAC pins.
Plug transformer into wall socket.
1
2
Connect one wire from each valve together with watertight
splice connectors; either valve wire will work.
Connect all wires to common terminals on timer.
1
2
Connect the second wire on each valve to a wire on the
control cable; connect only one valve to each wire.
Connect the other end of the wire to the desired zone
on the Timer (1,2,3, etc.).
(Each numbered zone corresponds to the same number zone
when programming timer)
Control Wire Connection
Zone 1
Zone 2
4
4
Connecting the Valve Wires: Control
5b
Remove the jumper wire from the Rain Sensor terminals.
Connect both Rain Delay Sensor wires to the terminals marked
RAIN SENSOR.
Common Wire Connection
1
2
Mounting Timer to wall
Drive a screw into the wall,
leaving 1/8” gap between head
and wall. (May also use supplied
wall anchors if necessary)
Hang Timer on exposed screw.
Remove access cover at
bottom of Timer and drive a
screw through the center hole
into wall.
1
2
3
24VAC
POWER
RAIN
SENSOR
COMMON
MSTR
VALVE
ZONE
1
ZONE
2
ZONE
3
ZONE
4
ZONE
5
ZONE
6
WATERING
DAYS
WATER
TIMES PER DAY
Choosing Timer location
1
2
System Check Out
7
To make sure each system is functioning properly, cycle
through each ZONE using the WATER NOW feature:
Do not
remove
wire unless
installing
Rain
Sensor
Do not
remove
wires unless
installing
Rain
Sensor
Do not
remove
wires
unless
installing
Rain Sensor
The SST Timer is for INDOOR use only. If you must install it outdoors, use a
water-resistant cabinet, such as the Rain Bird Model TC-2 Timer Cabinet. The
TC-2 is a heavy-duty, weather-resistant plastic case that lets you convert any
indoor-only timer to outdoor use.
DO NOT plug in the transformer until you have completed and
checked all wiring connections. Also, do not attempt to link two
or more timers together with a single transformer.
The SST Series Timers can be used with most hydro-indexing valves. Please
contact the valve manufacturer for more information. DO NOT connect more
than one valve wire to each terminal. Wiring more than one valve to each
terminal will damage the timer. Also, if you are using more than one timer, do
not share “common” wires between them.
USER TIP:
Use watertight splice connectors to prevent corrosion and avoid
short circuits.
USER TIP:
To save water and money, you can also install a rain sensor,
such as Rain Bird’s RS-1 Rain Shut Off. A rain sensor measures rainfall
and prevents unnecessary watering.
STOP
STOP
STOP
STOP
Turn the dial to the
ZONE you wish to test
and press WATER NOW.
The ZONE will start
watering for a default
10 minutes.
Use the Up/Down
arrows to adjust
the time.
To stop watering
before the time is up,
turn dial.
Repeat on next ZONE
until all have been
checked.
Master Valve or Pump Start Relay
8
USER TIP:
Make sure that the
total draw of the Master Valve or
Pump Start Relay plus the draw of
the valve does not exceed 0.650
Amps at 24 VAC, 60 Hz.
This Timer does not provide the
main power for a pump.
This example shows what a Master
Valve connection would look like.
A Pump Start Relay would connect
differently at the water source
If you decide not to use a Rain Sensor with the timer, leave the wire
jumper in place that connects the 2 terminals; timer will not work if
wire jumper is removed and sensor is not connected.
Included only on select models
1
2
3
4
5
Set dial to
desired ZONE
and press
WATER NOW
SST 600 Series Timers allow a master
valve or pump start relay to operate
whenever a valve is operating (pumps
are used in some places to draw
water from a well or other source).
If you are activating a pump from the
Timer, you must also install a Pump
Control Relay, such as Rain Bird’s
PCR-1. The PCR-1 can activate most
120– or 240–volt pump motors up to
2 horsepower.
STOP
e
1
2
3
P/N# 637234 REV. B
Do not
remove
wire unless
installing
Rain Sensor
In the interest of product improvement, Rain Bird reserves the right to change
product design or specifi cations without notifi cation.
®Trademark of Rain Bird Corporation.
© 2006 Rain Bird Corporation.
Rain Bird Corporation Consumer Products Division
Customer Service Center
6991 E. Southpoint Rd. Building #1
Tucson, AZ 85706
1-800-RAIN BIRD
Przeglądanie stron 0
1 2 3 4 5 6 7 8 9 10

Podsumowanie treści

Strona 1 - 24VAC pins

Water SourceConnect the color-coded “hot” wire from the Master Valve or Pump Start Relay to the Timer terminal marked MASTER (MSTR) VALVE.Connect the

Strona 2

Water SourceConnect the color-coded “hot” wire from the Master Valve or Pump Start Relay to the Timer terminal marked MASTER (MSTR) VALVE.Connect the

Strona 3

Water SourceConnect the color-coded “hot” wire from the Master Valve or Pump Start Relay to the Timer terminal marked MASTER (MSTR) VALVE.Connect the

Strona 4

Water SourceConnect the color-coded “hot” wire from the Master Valve or Pump Start Relay to the Timer terminal marked MASTER (MSTR) VALVE.Connect the

Strona 5

Water SourceConnect the color-coded “hot” wire from the Master Valve or Pump Start Relay to the Timer terminal marked MASTER (MSTR) VALVE.Connect the

Strona 6

Water SourceConnect the color-coded “hot” wire from the Master Valve or Pump Start Relay to the Timer terminal marked MASTER (MSTR) VALVE.Connect the

Strona 7

Water SourceConnect the color-coded “hot” wire from the Master Valve or Pump Start Relay to the Timer terminal marked MASTER (MSTR) VALVE.Connect the

Strona 8

Water SourceConnect the color-coded “hot” wire from the Master Valve or Pump Start Relay to the Timer terminal marked MASTER (MSTR) VALVE.Connect the

Strona 9

Water SourceConnect the color-coded “hot” wire from the Master Valve or Pump Start Relay to the Timer terminal marked MASTER (MSTR) VALVE.Connect the

Strona 10

Water SourceConnect the color-coded “hot” wire from the Master Valve or Pump Start Relay to the Timer terminal marked MASTER (MSTR) VALVE.Connect the

Komentarze do niniejszej Instrukcji

Brak uwag